LINDA Fact Sheet
| Electronics boards (2) |
Size |
177.5 x 122.1 mm |
|
|
|
| Booms (2) |
Weight incl. probe and cable |
80 g per boom |
| |
Retaining mech. Weight |
20 g per boom |
| |
|
|
| Spherical probes (2) |
Size |
10 mm diameter |
| |
Material |
Titanium |
| |
Surface treatment |
TiN |
| |
|
|
| Density signal, n |
Sampling frequency |
16 Hz (512 Hz during sweep) |
| |
Resolution |
16 bits, 2 ranges (preamp lo/hi) |
| |
Probe current limits |
10-10 to 5 10-5
A |
| |
Density limits |
107 to 5 1012 m-3 |
| |
Low pass filter |
8 Hz |
| |
|
|
| Relative density signal, dn/n |
Sampling frequency |
8192 Hz |
| |
Resolution |
8, 10 or 12 bits |
| |
Amplitude |
Corresp to 0.01 - 50% of n |
| |
Low pass filter |
4 kHz |
| |
High pass filter |
10 Hz |
| |
|
|
| Telemetry |
Average bit allocation to LINDA |
16 kbits/s (out of 128) |
| |
For 2 DC signals |
0.5 kbits/s |
| |
For 2 AC signals |
15 kbit/s |
| |
For status and others |
0.5 kbits/s |
| |
Buffer memory |
<2 Mbytes |
|